{"envelope_community":"ce_registry","envelope_id":"f85997f3-bc9d-4512-93f7-0119e88e20ab","envelope_ceterms_ctid":"ce-e98cf4de-fd5a-4285-9267-7411fd9fb7be","envelope_ctdl_type":"ceterms:AssessmentProfile","envelope_type":"resource_data","envelope_version":"1.0.0","decoded_resource":{"@context":"https://credreg.net/ctdl/schema/context/json","@id":"https://credentialengineregistry.org/graph/ce-e98cf4de-fd5a-4285-9267-7411fd9fb7be","@graph":[{"@id":"https://credentialengineregistry.org/resources/ce-e98cf4de-fd5a-4285-9267-7411fd9fb7be","@type":"ceterms:AssessmentProfile","ceterms:ctid":"ce-e98cf4de-fd5a-4285-9267-7411fd9fb7be","ceterms:name":{"en-US":"Fiber Optics Installer (FOI) Exam"},"ceterms:ownedBy":["https://credentialengineregistry.org/resources/ce-6845dbaa-3197-42f7-8054-32508f34ec8c"],"ceterms:assesses":[{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-927470c6-a2fd-4260-baa5-e90bdc535147","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"1.0 HISTORY OF FIBER OPTICS AND BROADBAND ACCESS"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-2f9e84e1-b43c-47bb-94dc-f73d1f9d0218","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"1.1 Trace the evolution of light in communications"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-580bb05b-45e1-4ae9-9756-b1ad440469aa","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"1.2 Summarize the evolution of optical fiber manufacturing technology"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-31ee9888-d535-4057-9f80-4d2030a81374","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"1.3 Track the evolution of optical fiber integration and application"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-8b130151-9058-4cd3-97ae-a521f0bdd605","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"1.4 Describe the role of fiber optics in high-speed Internet access"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-c06d0232-ad72-4d20-899b-83f87f2c3f19","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"10.0 FIBER OPTIC LIGHT SOURCES"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-547fc4c1-41e7-44a9-8c71-839f85c64632","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"10.1 Describe the basic operation and types of LED light sources used in fiber optic communications"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-765e9336-10a6-4391-bcf8-b8df2298fc2b","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"10.10 Explain the safety classifications of the light sources used in fiber optic communication"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-4d5ac6a5-34c0-4b92-82ac-31642aa8c2df","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"10.2 Describe the basic operation and types of laser light sources used in fiber optic communications"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-017c504a-9d34-4a16-aa8f-26e25797e302","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"10.3 Describe LED performance characteristics"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-074072e3-b996-4e5e-9103-ace7a79b2ca6","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"10.4 Describe laser performance characteristics"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-7959dc0e-c424-4dfb-8e5e-918f54be9869","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"10.5 Describe the performance characteristics of an LED transmitter"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-e3c54a2b-be02-4dcd-9a01-ac9967ace153","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"10.6 Describe the performance characteristics of a laser transmitter"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-571e7433-570e-46b4-a962-f3b01d2ac429","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"10.7 Explain the difference between a serial and parallel laser transmitter"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-3eaab9ca-b6f0-470b-b0ef-6e9850d56422","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"10.8 Describe the laser types and wavelengths associated with serial and parallel laser transmitters"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-3dc1b686-09af-488a-90a1-34ca9f9588e1","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"10.9 Describe the optical fiber types associated with VCSEL (Vertical Cavity Surface Emitting Laser) serial and parallel laser transmitters"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-86c0090a-e915-43c6-8a97-d4b6f17af5cf","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"11.0 FIBER OPTIC DETECTORS AND RECEIVERS"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-82699b3a-6af8-4a4f-b459-82b8a55e19b7","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"11.1 Describe the basic operation of a photodiode"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-05411530-eed3-434c-ae00-89a8e3a7386a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"11.2 Describe the basic components in a fiber optic receiver"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-13de0edc-01e7-4e7c-bc15-d5cf751a06eb","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"11.3 Explain dynamic range and operating wavelength"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-540a1ef5-11ca-4f84-a7fd-00671ae9fd12","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"11.4 Explain why an optical attenuator may be used in a communication system"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-8932fe1d-8992-45d3-aa76-48ea11e6dbad","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.0 CABLE INSTALLATION AND HARDWARE"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-ff752d7a-46d8-4b2c-8cfd-228f3d83d5bb","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.1 Explain manufacturer installation cable specifications"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-f9315814-cd10-417d-982e-b97e775f10a7","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.10 Recognize that ANSI/TIA-606- concisely describes the administrative record keeping elements of a modern telecommunications infrastructure"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-f10f7e16-e506-40fc-ad41-6277c3512f7d","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.11 Explain that the administration includes basic documentation and the timely updating of drawings, labels, and records"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-299a97b0-f9df-4c8d-bcd8-2d1c201d8c15","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.12 Explain why proper polarity is required to ensure the operation of bidirectional fiber optic communication systems"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-5acd66da-cf8c-4f5e-ab7c-b7de5f6f7395","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.13 Explain the roles of the following:"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-db811c39-7802-4f8a-8c38-d25646bcf0d2","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.13.1 National Electrical Code (NEC?)"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-9397f65b-ac94-4860-9d42-8aa4ef6837a5","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.13.2 Canadian Electrical Code (CEC)"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-6f7321c3-a83e-4351-99c3-ceefcc69f46b","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.13.3 National Electrical Safety Code (NESC?)"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-5781f1f3-f342-48ab-9cb5-a17b1b09a28c","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.2 Discuss ANSI/TIA-568- performance specifications for the optical fiber cables recognized in premises cabling standards to include:"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-516955b6-092b-4bcc-9b37-ca1d493eec76","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.2.1 Inside plant cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-961bb793-f342-45bb-8c7f-2a91fc1c810b","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.2.2 Indoor-outdoor cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-3a1ea074-709b-4893-8125-0ed2c1af2c8b","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.2.3 Outside plant cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-126834fc-d249-41d8-aa18-4c3b5fa70973","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.2.4 Drop cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-84055030-721c-4459-b63d-25c23c2f6f6d","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.3 Explain the static and dynamic loading on a fiber optic cable during installation"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-1bfd749c-fa79-48fd-9b24-f766e6325105","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.4 Describe commonly used installation hardware"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-fa567376-bc21-476b-89ea-ccf5b14c4b91","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.5 Summarize the following types of preparation:"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-234782f1-e7c9-4742-b95a-29a290ae918b","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.5.1 Patch panel"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-34084df9-a828-4fb8-8c7b-47094bf54921","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.5.2 Racks and cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-f257edb1-4c2b-4247-a633-c9c0ea31f582","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.5.3 Splice enclosure"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-fc713708-88e6-4c89-9f5f-68a768dfabb3","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.6 Describe the following types of installations:"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-ea7e6dcc-ad73-43b8-91dc-870be9bc2234","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.6.1 Tray and duct"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-ab55ef74-a242-4914-a9a6-41957ec0784d","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.6.2 Conduit"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-cfeb566a-f65d-4b0a-be0c-52f660bc607b","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.6.3 Direct burial"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-40b3c103-43be-4ea6-bd59-d89b291b3368","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.6.4 Aerial"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-4ccb4430-49fb-42cf-9973-d332f5ae877a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.6.5 Blown fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-1b1edef6-7709-4b6d-a7b0-8ddce659635d","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.6.6 Wall plate"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-6eae77b6-2628-4d1d-8648-238df9cec1eb","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.7 Describe the permitted locations defined in NEC Article 770 for the following cables:"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-d222c060-9b32-4d22-846c-69f0b0ee1291","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.7.1 Plenum"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-f329d5b7-bf19-474b-8242-696e176e810d","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.7.2 Riser"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-16785f22-d3f7-459e-bf05-e85dc2aa9c6a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.7.3 General-purpose"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-c736339e-edb6-407e-a5f9-8809e1123792","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.7.4 Unlisted conductive and nonconductive outside plant cables"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-80341fb6-8dd8-496a-9dbf-7cf432735290","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.8 Describe the NEC fiber-optic cable types that might require grounding or isolation."}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-132f1d3b-391e-47af-ad30-4cd568aa05da","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"12.9 Explain entrance cable bonding and grounding per NEC Articles 250, 770.93, and 770.100"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-7d92f1c6-5079-417e-bd2b-7020772803f3","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"13.0 FIBER OPTIC SYSTEM ADVANTAGES"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-e7ec6848-15af-47f2-9da1-68ba2ac853f8","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"13.1 Compare the bandwidth advantages of optical fiber over twisted pair and coaxial copper cables"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-98b19fe0-001e-419d-9d09-ed3146fdc526","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"13.2 Compare the attenuation advantages of optical fiber over twisted pair and coaxial copper cables"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-e9d4ef73-619c-48ce-b9b2-391ddbff7638","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"13.3 Explain the electromagnetic immunity advantages of fiber optic cable over copper cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-0d70b9da-14fa-4771-a384-f86770afb55e","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"13.4 Describe the size advantages of fiber optic cable over copper cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-a6e2e53b-1c39-4db1-ac4f-edda05c9f4ed","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"13.5 Describe the weight-saving advantages of fiber optic cable over copper cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-e6c01b72-8de1-4948-94db-a6713a189142","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"13.6 Describe the security advantages of fiber optic cable over copper cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-71d13aa4-6a0c-40d2-86ea-9bfd99ef0b94","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"13.7 Compare the safety advantages of fiber optic cables over copper cables"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-e99ccc3a-a7cc-4053-afb4-08b2297fb6fa","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.0 TEST EQUIPMENT AND LINK/CABLE TESTING"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-873af76d-f107-4d15-a759-a47daa3d6a9a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.1 Explain why test equipment calibration should be traceable to the National Institute of Standards and Technology (NIST?) calibration standard"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-3b2f0054-f2ac-4178-888c-6beba07cd2c7","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.10 Explain why multimode insertion loss measurements being performed in accordance with ANSI/TIA-526-14- require a modal controller on the transmit jumper"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-59b8dc37-04e5-4c9a-b318-b0ae0fc74649","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.11 Describe how to measure the optical loss in a patch cord with an OLTS using the steps described in ANSI/TIA-526-14, method A, two-test jumper reference"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-773b22a6-63c4-4c26-b129-420d33c25dbb","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.12 Summarize the basic operation of an optical time domain reflectometer (OTDR)"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-6c157845-5f8d-43ea-bd2c-d6bebcc8a18e","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.13 Describe the required Tier 1 Testing tasks and equipment"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-5f7220c0-1255-4c57-99a6-d6e164660935","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.14 Describe the required Tier 2 Testing tasks and equipment"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-0ce48b32-8f72-43a1-a5a6-f3bdd3ef5ec5","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.2 Describe the types of fiber optic test equipment that can be used to test for continuity"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-1c41e6a0-16ce-4f40-ab22-0fc567a39299","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.3 Explain the use of a visual fault locator (VFL) when troubleshooting a fiber span"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-ed3e8da0-df43-4162-a48e-980f285baf10","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.4 Describe the basic operation of a multimode and single-mode optical loss test set (OLTS)"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-cdebec84-8de8-414a-89d5-1fbacb1d6c40","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.5 Explain the difference between a patch cord and a measurement quality jumper (MQJ)"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-309143be-edb1-47d4-abac-69ad4985c68d","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.6 Define the purpose of a mode filter"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-2e26c952-58b4-458b-b6dd-715d438e75fd","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.7 Explain why five small-radius nonoverlapping loops around a mandrel may be required on the transmit jumper when measuring multimode link attenuation in accordance with ANSI/TIA-526-14-A"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-7235d231-f988-45ca-8abc-7d0ad10d98e9","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.8 Explain why a single turn 30mm in diameter loop must be applied to the transmit jumper when measuring single-mode link attenuation in accordance with ANSI/TIA-526-7"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-b3af15ab-49ac-4b42-ba2d-3f70a12b73e8","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"14.9 Explain why the encircled flux requirement was developed for multimode link attenuation measurements"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-fb2fff9d-bbed-4502-959f-677b90cc8fe2","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"2.0  PRINCIPLES OF FIBER OPTIC TRANSMISSION"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-3d218b57-fdb9-4337-9a6b-eb51d732bea7","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"2.1 Describe the basic parts of a fiber-optic link"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-1c385899-e662-49eb-9f5b-339f74958a1a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"2.2 Describe the basic operation of a fiber-optic transmitter"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-427cbfb0-42c6-4f3c-8bda-7bacdd9519e7","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"2.3 Describe the basic operation of a fiber-optic receiver"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-2daa829b-5552-4ec4-b4c5-c040d762eff7","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"2.4 Explain how to express gain and loss using the decibel (dB)"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-4ffe7695-79ae-4e15-bf98-f39d3b957fe1","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"2.5 Explain how to express optical power in dBm (measured power referenced to one milliwatt)"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-b7dd0d2d-5fed-4d0b-a029-75aa099ce384","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"3.0 BASIC PRINCIPLES OF LIGHT"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-339ef116-c72f-443d-842f-997a3b112089","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"3.1 Describe light as electromagnetic energy"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-a7efe754-0477-40c0-8513-7b15cc93e02d","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"3.2 Describe light as particles and waves"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-d9abd696-53f4-4e5e-bc9e-00539db7704b","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"3.3 Describe the electromagnetic spectrum and locate light frequencies (wavelengths) within the spectrum in relation to radio and microwave communication frequencies"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-e178856e-172a-4f3a-a9a3-17682378aed4","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"3.4 Describe the refraction of light"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-1e7dcad6-ac86-48ad-ab67-44bf7834cf08","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"3.5 Explain how the index of refraction is used to express the speed of light through a transparent medium"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-2e99c774-75b8-4ff8-8375-6b965cfdfeb3","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"3.6 Explain reflection to include angle of incidence, critical angle, angle of refraction, and total internal reflection"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-04404ff1-1e2e-4543-bbb7-36fc46b00170","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"3.7 Explain Snell?s law and its use to calculate the critical angle of incidence"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-56ec587e-64a8-49da-a102-ef3bcc3b418c","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"3.8 Explain Fresnel reflections and how they impact the performance of a fiber optic communication system"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-b7992d59-5ca5-4df5-97d6-d4811d593aa0","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.0 OPTICAL FIBER CONSTRUCTION AND THEORY"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-bb391845-0cc2-4a5b-8e27-1fc9b2fb73d4","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.1 Describe the basic parts of an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-100962e3-7c1f-4655-9b2e-ae8cdba009db","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.10 Explain the propagation of light through a multimode graded index optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-5bfdaf28-f213-49c7-8059-885fdda58b4a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.11 Explain the propagation of light through a single-mode optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-772424d7-55de-4eb1-98fd-260a788e08e2","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.12 Describe the location and function of an optical trench"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-1ed91462-159c-4b0e-8a72-8351c3153266","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.13 Describe the advantages of single-mode and multimode bend insensitive optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-42759575-e806-4539-bc46-82f29af6a5cf","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.2 List the major standards organizations that publish standards that define the performance of optical fibers used in the telecommunications industry"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-066a8140-0e7f-49e4-a1fd-ea1165e2197a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.3 List the different materials that can be used to construct an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-472fef91-36c6-4cf1-937b-6c1267b37d6c","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.4 Describe the tensile strength of an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-fbc9c6ac-2229-4d90-b8fc-0591e70c6198","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.5 Describe optical fiber manufacturing techniques"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-86a102a1-db42-4f0a-9f35-1ffd27eaa569","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.6 Describe mode in an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-be6f9152-2d91-41bc-b554-ca944711693e","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.7 Describe how the number of modes in an optical fiber is defined by core diameter and wavelength"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-bc742a39-0b52-46d0-8e2f-617ad9868c86","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.8 Describe the refractive index profiles commonly found in optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-938ae985-bc52-4704-b137-9604187b52bc","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"4.9 Explain the propagation of light through a multimode step index optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-0dddf8ab-ffb1-4fc7-95d7-b6b927f15a6b","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.0 OPTICAL FIBER CHARACTERISTICS"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-e2a35f74-a1ec-4c8e-950d-f0da45783804","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.1 Describe dispersion in an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-0df0e7c3-32ba-446e-ae19-398fada6e9c0","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.10 Describe a microbend in an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-dff484a7-08fd-4517-8ad3-0aa42ef4133a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.11 Describe a macrobend in an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-8d15dea0-7994-4d34-a3fa-07a7e3031347","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.12 Explain the difference between a bend sensitive and bend insensitive single-mode optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-d66ac85d-9d98-402a-a4a6-9cadcbcc6b08","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.13 Explain the difference between a bend sensitive and bend insensitive multimode optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-71481ec4-942d-4841-9e36-3c3001c5cba6","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.14 Describe the numerical aperture of an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-18f6de70-4f29-4eff-82cf-c5e88f56c8c7","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.15 Explain how optical fibers are designated in ISO/IEC 11801"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-9c25a275-66a1-4aa9-be77-8997b8a444b5","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.16 Explain how optical fibers are designated in IEC 60793-2-10 and IEC 60793-2-50"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-73bc686c-2016-4ec3-8b1e-5de6d6f8c9f4","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.17 Describe how optical fibers are designated in ANSI/TIA-568-"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-7f05b144-76ac-4218-a639-d342f281537c","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.18 Describe how the International Telecommunications Union (ITU ) designates optical fibers"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-fc454b54-6c4a-4179-acfc-f76436430d8a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.19 Describe the performance characteristics of ANSI/TIA-568- and ISO/IEC 11801-recognized optical fibers"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-7bfd3c27-4419-472e-b1cb-edd1368d667b","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.2 Describe modal dispersion and its effects on the bandwidth of an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-c328888f-bb68-4d62-9a38-9eabd81bc15f","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.20 Describe the performance characteristics of ITU-T G.652, ITU-T G.655, and ITU-T G.657 singlemode optical fibers"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-d7f9fdbb-6061-41f8-af20-012a0444d006","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.21 Describe the attenuation and bandwidth characteristics of HCS/PCS (Hard Clad Silica/Plastic Clad Silica) and plastic optical fibers"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-54b15b93-40fd-4f85-97e2-7fed5261a616","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.3 Describe material dispersion and its effects on the bandwidth of an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-3c63025f-f492-43b6-a90f-09380a051907","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.4 Explain waveguide dispersion in a single-mode optical fiber."}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-4769831a-c40e-47ed-8e9a-6198d1cf6f0a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.5 Explain chromatic dispersion in an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-4c927e40-f8c7-4562-8265-778a75edbbee","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.6 Explain polarization mode dispersion in a single-mode optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-c67c9a67-bb1b-47c7-bd07-a069e9c89ae1","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.7 Describe how dispersion affects bandwidth in an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-01c8368e-1a48-4034-9544-2e3d69858d2e","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.8 Describe the causes of attenuation in an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-987052b1-6d6e-447f-b17a-d0a504e5af8b","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"5.9 Describe attenuation versus wavelength in an optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-aec896ea-f513-4103-b5ac-b018d48bfcd1","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"6.0 FIBER OPTIC SAFETY"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-ad34371e-41ec-4226-92ee-c11a1641667d","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"6.1 Cite the government agency that publishes and enforces regulations on safety in the workplace"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-a5cf68c0-3d75-4fc0-839b-50bd64aa88de","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"6.2 Explain how to safely handle and dispose of fiber optic cable and bare optical fiber"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-21053fa4-682d-40f0-befb-d052d36fe839","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"6.3 List the laser hazard classifications of fiber optic light sources and describe the dangers associated with each"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-28e38e44-cec9-497e-8fbb-0ec9140469a2","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"6.4 Describe potential chemical hazards in the fiber optic environment and explain the purpose of the material safety data sheet (MSDS or SDS)"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-5eabbbe2-4312-423b-a971-96d9251d6184","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"6.5 Describe potential electrical hazards in the fiber optic installation environment"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-a043dacc-5ba6-425b-a4d2-2ca4dea63915","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"6.6 Describe typical work place hazards in the fiber optic environment"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-4c6dd813-b3d1-4270-9684-644fe85efc38","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.0 FIBER OPTIC CABLES"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-5de11cff-f90c-475b-9c64-7cd79ea8713d","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.1 Explain the purpose of each component displayed in a cross section view of a fiber optic cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-171d5456-a579-4812-9bd8-a39b2ca4b3a1","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.10 Explain how and when a breakout kit is used"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-c6e5c4e6-b7dd-4c7b-a8d4-d4a33029e041","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.11 Describe the National Electrical Code (NEC) fiber-optic cable types"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-e12f4335-2e34-48ce-8dcf-af18cc7219f5","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.12 Describe the NEC listing requirements for fiber-optic cables"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-69a48ce8-06cc-4c27-be77-1e9905b8bec4","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.13 Explain the difference between a listed and nonlisted fiber-optic cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-ba184f38-0899-4a88-8141-b1ed56c6b958","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.14 List the types of markings typically found on the jacket of a fiber-optic cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-2cff3397-87c6-41b2-b410-e55edca0cb73","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.15 Describe the TIA-598- color-coding scheme for individual fibers bundled in a fiber-optic cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-8dbdddaa-0d71-48e2-80dc-bf9a1a1f151a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.16 Describe the TIA-598- color-coding scheme for premises cable jackets"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-14af20e9-c555-40e3-b1df-13e4510a6a3c","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.17 Explain how numbering is used to identify the individual fibers bundled in a fiber-optic cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-bb07cf78-4637-40bb-857b-993318bb7f75","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.18 Describe how to use sequential markings to determine fiber-optic cable length"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-d558933a-593a-4b1f-bd3b-1d40ebca6374","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.2 Explain why and where loose buffer fiber optic cable is used"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-f43b272d-c424-4a2f-a501-c6c7f0f8762e","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.3 Describe the difference between gel-filled and gel-free loose buffer fiber optic cables"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-2d6244df-b1db-4726-810d-aa6ed06a4280","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.4 Describe tight buffer fiber optic cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-fce7dc4f-8bbf-4a35-bbd0-c4470987e1a9","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.5 Compare common strength members found in fiber optic cables"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-b0ff1b80-287f-44bf-97df-8724b013d95d","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.6 Name common jacket materials found in fiber optic cables"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-8f23f2a6-f7fb-42d6-a229-63f0ecc75f78","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.7 Describe simplex and duplex cordage and explain the difference between cordage and cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-4c001bcc-3548-4203-9b69-502a0f368637","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.8 Describe the characteristics of the following:"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-f74eff86-83ae-466c-8ca0-edf8d967f665","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.8.1 Distribution cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-b94391e7-d4a8-48f3-adf4-5d0ecd4af810","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.8.2 Breakout cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-699dd7d8-dd9b-4220-b486-cb020af62eef","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.8.3 Armored cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-03839d81-f655-4cda-bb78-17832ad2c896","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.8.4 Messenger cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-9614dd4a-a6a5-4e7a-a006-17cb442a63ac","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.8.5 Ribbon cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-a3fc046b-2e07-4b12-b8aa-c620fd624bad","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.8.6 Submarine cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-608f950f-36ac-4ae2-8d58-67f832104ad1","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.8.7 Hybrid cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-a4560897-5a6d-469b-a73b-2a3abb5a6063","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.8.8 Composite cable"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-3ef42c0d-a61b-4af7-8b1a-cfd247534d19","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"7.9 Explain how and when a fan-out kit is used"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-60cdfd61-fe12-486f-929e-d927de921906","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"8.0 SPLICING"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-5a18fb19-25b1-4d55-bc02-6ba46d6a441a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"8.1 Describe the intrinsic factors that affect splice performance"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-4ff85b02-3142-4eeb-94b8-33312ac393af","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"8.10 List ANSI/TIA-758- and Telcordia GR-20 outside plant splice performance requirements"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-4208dc4e-3983-456e-923c-8f820043e796","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"8.11 Describe the Telcordia GR-765 required and objective fusion splice insertion loss requirements for passive and active alignment splicers"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-7e9be6c5-25a6-4ff2-96de-e3e396c27336","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"8.2 Describe the extrinsic factors that affect splice performance"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-77d3826e-1204-400a-b618-e87d9d5e4ef4","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"8.3 Explain how a mechanical splice creates a low loss interconnection"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-b2a5bb8b-a8cd-4f84-90ea-2083e325bf61","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"8.4 Describe how to assemble a mechanical splice"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-3cc99b1f-36d1-4919-b60e-d76b0c2d1b88","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"8.5 Explain how a fusion splicer creates a low loss interconnection"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-c18c4ce2-d194-4df9-8428-d2c88d46dcff","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"8.6 Describe the basic operation of a fusion splicer"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-9c809270-0643-43b5-a283-b2e0b8e42b95","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"8.7 Describe the different alignment techniques that can be used to align the optical fibers"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-86939aa0-5d5d-4cf2-9b7f-32b3615b3423","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"8.8 Explain how to assemble and protect a fusion splice"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-491b5ea6-4424-4927-8056-130502ba47ef","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"8.9 List the ANSI/TIA-568- inside plant splice performance requirements"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-958de9ab-7a51-48f1-8d5c-87b316a7ee27","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.0 CONNECTORS"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-af4ad1a4-8ca0-4966-b0d0-d72a9f36925a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.1 Describe the basic components of a fiber optic connector"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-ffc8d70d-8572-4dc4-a212-20711dec252e","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.10 Explain the difference between a contact and noncontact connector"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-2fff8e6f-dcd2-4f43-b559-085adffbf368","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.11 Describe the ANSI/TIA-568- recognized connectors"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-230c80ce-d86a-43e3-842c-b059f9f4d45f","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.12 Describe small form factor connectors"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-015955f9-d171-4b15-b1d0-5654b2b7d180","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.13 Describe MPO connectors"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-bae13ead-7999-41e9-a2d5-91cdeb9c4cd2","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.14 Describe a pigtail and the potential advantages it offers over field terminations"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-eff5f323-7a29-42b0-b7e7-244c88991152","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.15 Describe the steps involved in an oven cured epoxy connector termination and polish"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-35140f8b-f02d-4095-a2f4-5dabcb6f591c","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.16 Describe the steps involved in an anaerobic epoxy connector termination and polish"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-e677a60a-e6e4-4580-bd49-7ed8d2694337","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.17 Explain how machine polishing produces a better, more consistent endface than hand polishing"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-1c644b85-653f-4069-9328-8a3ad43c38d0","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.18 Describe pre-polished connector termination techniques"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-ff686c43-4a29-429d-ab10-1a55ffd32cb5","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.19 Explain how to properly clean a connector endface using dry cleaning techniques"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-58dd23ea-9c39-4492-8fb3-1198de3f4dbc","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.2 Describe common connector ferrule materials"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-47769c58-0a69-4a2f-9a68-5ce48f3fe9e4","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.20 Explain how to properly clean a connector endface using wet-dry cleaning techniques"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-cdb618ea-9389-43f9-9d1a-244a8e34f32b","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.21 Explain how to examine the endface of a connector per ANSI/TIA-455-57- and IEC 61300-3-35"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-3b44b6c1-490c-435c-9260-38bb421ca72a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.22 List the ANSI/TIA-568- maximum insertion and return loss values for multimode and singlemode mated connector pairs"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-1f88f83b-b6f8-4b7e-a28c-cbb65dbd6f2e","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.23 List the ITU-T G.671 maximum insertion loss and reflectance values for single-mode single-fiber mated connector pairs"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-170d05d2-94a2-4917-adc5-384de17e9a69","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.24 Explain how to use the ANSI/TIA-568- color code to identify multimode and single-mode connectors and adapters"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-03ecfa00-7d5f-4a64-9860-2ff2ba236315","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.3 List the intrinsic factors that affect connector performance"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-c0be52cc-cde4-43ac-aaa3-81add3861b99","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.4 List the extrinsic factors that affect connector performance"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-d6a88ea1-14eb-4c89-9cc1-674ab3a5987e","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.5 Describe the following endface geometries:"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-6387a649-a6ce-4055-8ee6-bab731beb3af","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.5.1 Flat"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-4d166a27-bcd7-4365-9cc6-ac35a8f5186a","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.5.2 Curved"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-832b6ac7-f8b5-4c44-8370-3c51df9fa762","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.5.3 Angled"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-cd697920-ac4b-4015-bf3a-aad20fc774c2","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.5.4 Lensed"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-ba1cd169-1196-4375-aba5-2f333f9589ab","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.6 Describe return or back reflections, return loss, and reflectance in an interconnection"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-36b379f7-2a77-424e-aa7b-327eb38baf50","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.7 Explain how endface geometry affects return loss and reflectance"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-7fccf751-763e-40ac-99a5-8f4860f7eb06","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.8 Describe how an interferometer is used in the evaluation of endface geometry"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-b75563e2-4247-4534-95ea-5636552f0606","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.9 Describe the following critical parameters that are required by Telcordia GR-326 to evaluate connector endface geometry for single-mode connectors and jumper assemblies:"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-f7c73af4-863d-48e5-a822-b19924b8bb82","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.9.1 Radius of curvature"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-86b889d0-7308-4ba2-9011-0a5238e45f23","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.9.2 Apex offset"}},{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credentialengineregistry.org/resources/ce-7afcbac1-d5cd-4273-89a4-2917d7ac9d22","ceterms:targetNode":"https://credentialengineregistry.org/resources/ce-aeae79ee-2fdd-4add-becc-b8bbccfa2ca5","ceterms:frameworkName":{"en-US":"Certified Fiber Optics Installer (FOI)"},"ceterms:targetNodeName":{"en-US":"9.9.3 Fiber undercut or protrusion"}}],"ceterms:inLanguage":["en"],"ceterms:description":{"en-US":"Applicants must pass the Fiber Optics Installer (FOI) Exam to earn credential."},"ceterms:estimatedCost":[{"@type":"ceterms:CostProfile","ceterms:name":{"en-US":"Exam Fees"},"ceterms:price":155.0,"ceterms:currency":"US Dollar","ceterms:costDetails":"http://www.etai.org/fiber_cabling.html#FOI","ceterms:description":{"en-US":"Must pass the FOI Exam to earn certification."},"ceterms:directCostType":{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credreg.net/ctdl/terms/CostType","ceterms:targetNode":"costType:StandaloneAssessment","ceterms:frameworkName":{"en-US":"Cost Type"},"ceterms:targetNodeName":{"en-US":"Standalone/Extra Assessment"},"ceterms:targetNodeDescription":{"en-US":"Cost for standalone assessments."}}}],"ceterms:subjectWebpage":"https://www.etai.org/fiber_cabling.html#FOI","ceterms:assessmentUseType":[{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credreg.net/ctdl/terms/AssessmentUse","ceterms:targetNode":"assessUse:Summative","ceterms:frameworkName":{"en-US":"Assessment Use"},"ceterms:targetNodeName":{"en-US":"Summative Assessment"},"ceterms:targetNodeDescription":{"en-US":"Assessment of learning at the end of an instructional unit to determine whether some established standard or benchmark has been achieved."}}],"ceterms:estimatedDuration":[{"@type":"ceterms:DurationProfile","ceterms:exactDuration":"PT2H"}],"ceterms:scoringMethodType":[{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credreg.net/ctdl/terms/ScoringMethod","ceterms:targetNode":"score:CriterionReferenced","ceterms:frameworkName":{"en-US":"Scoring Method"},"ceterms:targetNodeName":{"en-US":"Criterion-Referenced"},"ceterms:targetNodeDescription":{"en-US":"Scored based on a comparison to defined criteria and levels of performance."}}],"ceterms:availabilityListing":["https://www.etai.org/test_sites.html"],"ceterms:lifeCycleStatusType":{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credreg.net/ctdl/terms/LifeCycleStatus","ceterms:targetNode":"lifeCycle:Active","ceterms:frameworkName":{"en-US":"Life Cycle Status"},"ceterms:targetNodeName":{"en-US":"Active"},"ceterms:targetNodeDescription":{"en-US":"Resource is active, current, ongoing, offered, operational, or available."}},"ceterms:assessmentMethodType":[{"@type":"ceterms:CredentialAlignmentObject","ceterms:framework":"https://credreg.net/ctdl/terms/AssessmentMethod","ceterms:targetNode":"assessMethod:Exam","ceterms:frameworkName":{"en-US":"Assessment Method"},"ceterms:targetNodeName":{"en-US":"Exam"},"ceterms:targetNodeDescription":{"en-US":"Mix of scored items presented in fixed or open response formats including qualifying and comprehensive exams."}}],"ceterms:scoringMethodDescription":{"en-US":"Must earn a 75% on exam to pass."}}]},"resource_format":"json","resource_encoding":"jwt","publisher_id":"e8aa2734-5f6d-473a-9cf7-bc184439a1ac","secondary_publisher_id":null,"resource_publish_type":"primary","node_headers":{"resource_digest":"Aa1dCw5ZOAwTBLMgwph7hCchG0pYxUMyKBp6CQRgaF4=","revision_history":[{"head":false,"event":"create","created_at":"2018-01-05T17:13:33.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab/revisions/5461"},{"head":false,"event":"update","created_at":"2018-02-26T05:09:59.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab/revisions/9145"},{"head":false,"event":"update","created_at":"2018-05-17T18:15:35.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab/revisions/9158"},{"head":false,"event":"update","created_at":"2018-05-17T18:43:03.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab/revisions/9867"},{"head":false,"event":"update","created_at":"2018-06-12T21:33:12.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab/revisions/15926"},{"head":false,"event":"update","created_at":"2018-10-16T23:09:41.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab/revisions/29780"},{"head":false,"event":"update","created_at":"2019-03-05T00:36:02.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab/revisions/29782"},{"head":false,"event":"update","created_at":"2019-03-05T00:41:54.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab/revisions/32977"},{"head":false,"event":"update","created_at":"2019-05-23T13:26:05.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab/revisions/56171"},{"head":false,"event":"update","created_at":"2020-02-18T04:40:26.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab/revisions/86158"},{"head":false,"event":"update","created_at":"2020-12-24T17:37:13.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab/revisions/86162"},{"head":false,"event":"update","created_at":"2020-12-24T17:37:26.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab/revisions/263817"},{"head":true,"event":"update","created_at":"2023-02-28T16:41:04.000Z","actor":null,"url":"/ce-registry/envelopes/f85997f3-bc9d-4512-93f7-0119e88e20ab"}],"created_at":"2018-01-05T17:13:33.000Z","updated_at":"2023-02-28T16:41:04.000Z","deleted_at":null},"owned_by":"ce-6845dbaa-3197-42f7-8054-32508f34ec8c","published_by":"ce-6845dbaa-3197-42f7-8054-32508f34ec8c","changed":false,"updated_at":"2023-02-28T16:41:04.829Z","last_verified_on":"2025-04-01"}